Thermal imaging quality control for silicon staves of the ATLAS phase II upgrade

Su Mo Tu We Th Fr Sa
27 28 29 30 31 1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30
Date/Time:Wednesday, 27 Apr 2016 from 4:10 pm to 5:10 pm
Location:A401, Zaffarano Hall
Contact:Chunhui Chen
Phone:515-294-5062
Channel:College of Liberal Arts and Sciences
Actions:Download iCal/vCal | Email Reminder
Mr. Carlos Miguel Vergel-Infante, Iowa State University

A new silicon strip detector is part of the phase II upgrade of the ATLAS inner tracker. Light-material carbon fiber honeycomb sandwich staves serve as mechanical support for the strip sensors and readout modules and to move the dissipated heat out of the detector. A cooling pipe inside the stave is embedded in heat-conducting foam that thermally connects the pipe with the readout modules. The staves are required to pass a set of quality control (QC) tests before they are populated with readout modules. One test uses a non-invasive inspection method of infrared (IR) thermal imaging of the heat path while the stave is cooled to around -40?C at ambient room temperature. Imperfections in the manufacturing, such as the delamination of the stave facing from the foam, will exhibit a different temperature profile compared to a flawless stave. We report on the current status of the thermal imaging QC measurements including a characterization of various contributions to the uncertainties in the temperature reading of the IR camera such as pedestal variations, common-mode noise, vignetting, and statistical fluctuations across the field of view.